6 – ENGLISH
3.5 PRE-INSTALLATION WORKS
The gure shows an example of an automation system, constructed using Nice components.
A4
C
5
4
E
1
2 3
F
D
D
6
G
B
B
5
A Gearmotor
B Photocells
C Key selector
D Photocells on column
E Warning light with incorporated antenna
F Transmitter
G Main edge
These above-mentioned components are positioned according
to a typical standard layout. Using the layout in “Figure 5as a
reference, dene the approximate position in which each com-
ponent of the system will be installed.
Table 4
TECHNICAL SPECIFICATIONS OF ELECTRICAL CABLES
Identication
no.
Cable characteristics
1
GEARMOTOR POWER SUPPLY cable
1 cable 3 x 1.5 mm
2
Maximum length 30 m [note 1]
2
WARNING LIGHT cable
1 cable 2 x 1 mm
2
Maximum length 20 m
3
ANTENNA cable
1 x RG58-type shielded cable
Maximum length 20 m; recommended < 5 m
4
PHOTOCELL cable
1 cable 2 x 0.5 mm
2
Maximum length 30 m [note 2]
5
KEY SELECTOR cable
2 cables 2 x 0.5 mm
2
[note 3]
Maximum length 50 m
6
MAIN EDGE cable
1 cable 2 x 0.5 mm
2
Maximum length 20 m
Note 1 If the power supply cable is longer than 30 m, a cable
with larger cross-sectional area (3 x 2.5 mm
2
) must be
used and a safety earthing system must be installed
near the automation.
Note 2 If the BlueBus cable is longer then 30 m, up to maxi-
mum 50 m, it is necessary to use a cable with a greater
cross-sectional area (2 x 1 mm
2
).
Note 3 These two cables can be replaced by a single 4 x 0.5
mm
2
cable.
a
Before proceeding with the installation, prepare the
required electrical cables by referring to “Figure 5
and to that stated in the “TECHNICAL SPECIFICA-
TIONS” chapter.
a
The cables used must be suited to the type of envi-
ronment of the installation site.
a
When laying the pipes for routing the electrical ca-
bles, take into account that any water deposits in
the junction boxes may cause the connection pipes
to form condensate inside the control unit, thus
damaging the electronic circuits.

Table of Contents

Other manuals for Nice SO2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nice SO2000 and is the answer not in the manual?

Nice SO2000 Specifications

General IconGeneral
BrandNice
ModelSO2000
CategoryGarage Door Opener
LanguageEnglish

Related product manuals