ENGLISH – 17
7.3 LEVEL 2 PROGRAMMING (ADJUSTABLE PARAMETERS)
All the Level 2 parameters are factory-set as highlighted in “GREY” in “Table 9” and can be modied at any time. The parameters
can be set to a scale of 1 to 8. The check the value corresponding to each LED, refer to “Table 9”.
7.3.1 Level 2 programming procedure
m
The user has maximum 10 seconds to press the buttons consecutively during the programming procedure,
after which time the procedure terminates automatically and memorises the changes made up to then.
To perform Level 2 programming:
1. press and hold the
o
button until LED “L1” starts ashing
2. release the
o
button when LED “L1” starts ashing
3. press the
p
or
q
button to move the ashing LED to the “entry LED” associated with the parameter to be modied
4. press and hold the
o
button. With the
o
button pressed:
– wait roughly 3 seconds, until the LED representing the current level of the parameter to be modied lights up
– press the
p
or
q
button to shift the LED associated with the parameter’s value
5. release the
o
button
6. wait 10 seconds (maximum time) to exit the programming mode.
l
To set multiple parameters during the procedure's execution, repeat the operations from point 2 to point 4 dur-
ing the phase itself.
Table 9
LEVEL 2 FUNCTIONS (ADJUSTABLE PARAMETERS)
Entry LED Parameter LED (level) Set value Description
L1* Pause Time
L1 10 seconds
Adjusts the pause time, in other words,
the time before automatic re-closure.
It is only effective if the “Automatic
Closing” function is enabled.
L2 20 seconds
L3 40 seconds
L4 60 seconds
L5 80 seconds
L6 120 seconds
L7 160 seconds
L8 200 seconds
L2**
Step-by-Step
function
L1 Open - Stop - Close - Stop
Controls the sequence of controls
associated with the Sbs input or the 1st
radio command.
L2 Open - Stop - Close - Open
L3 Open - Close - Open - Close
L4 Condominium
L5
Condominium 2 (more than 2 sec triggers
“Stop”)
L6
Step-by-Step 2 (less than 2 sec triggers “Partial
Open”)
L7 Hold-to-run
L8
Opening in “semi-automatic” mode, closing in
“hold-to-run” mode
L3* Motor speed
L1 Speed 1 (30% - slow)
Adjusts the motor speed during normal
manoeuvres.
L2 Speed 2 (44%)
L3 Speed 3 (58%)
L4 Speed 4 (72%)
L5 Speed 5 (86%)
L6 Speed 6 (100% - fast)
L7 Open V4, close V2