BATTERY CHARGING [MICROMATIC M17B]
NOTE
Charge the batteries when the warning light (3) or (4) turns on, or when nishing cleaning.
Keeping the batteries charged makes them last longer.
CAUTION!
When the batteries are discharged, charge them as soon as possible, as that condition makes them last shorter.
Check for battery charge at least once a week.
WARNING!
When using lead (WET) batteries, battery charging produces highly explosive hydrogen gas. Charge the
batteries in well-ventilated areas and away from naked ames.
Do not smoke while charging this type of batteries.
During the charging of this type of batteries, the recovery water tank (A) must be removed.
WARNING!
When using lead (WET) batteries, be extremely careful while charging the batteries as there may be battery uid
leakages. The battery uid is corrosive. If it comes in contact with the skin or eyes, rinse thoroughly with water
and consult a physician.
CAUTION!
Batteries must be charged indoors, in a dry environment (damp free).
Preliminary procedures
Drive the machine on a level ground.
Check that the switches (5 and 6) are turned to “0”.
If there is recovery water in the tank (43), drain it through the hose (22).
For lead (WET) batteries only:
Disconnect the vacuum hose (29) from the squeegee (17).
Open the cover (12).
Grasp the recovery water tank (A) in the area (B) and lift it, as shown in the gure, then disconnect the vacuum hose (C)
from the tank and remove the tank (A) together with the hoses (D) and (E).
Check for the correct level of electrolyte inside the batteries (50). If necessary, add distilled water through the caps.
Leave all the battery caps open for next charging.
If necessary, clean the upper surface of the batteries.
Charge the batteries according to one of the following procedures, depending on the presence of the battery charger (33).
1.
2.
3.
4.
5.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nilfisk-Advance Micromatic M17B and is the answer not in the manual?

Nilfisk-Advance Micromatic M17B Specifications

General IconGeneral
BrandNilfisk-Advance
ModelMicromatic M17B
CategoryFloor Machine
LanguageEnglish

Related product manuals