Maintenance and Servicing | 60
Required Maintenance
The NHTC/PC humidifier has been designed to require very little maintenance. Regular
maintenance consists of checking the humidifier to insure it is in good condition, replacing the
cylinder when the software advises that the cylinder is spent and cleaning out the drain valve
whenever the cylinder is replaced.
Cylinder Spent Warning / Fault
The steam cylinder is disposable and must be replaced at end of cylinder life. Cylinder life is
dependent on water supply conditions and humidifier usage. Failure to replace the cylinder at
the end of cylinder life will cause the unit to lock out. NORTEC is not responsible for any
damages resulting from, or attributed to, the failure to replace a spent cylinder (see
Manufacturer’s Warranty).
Warning
When the software
determines that cylinder is
spent it first displays a
warning and turns on the
yellow service LED. The
humidifier will continue to
operate for another 72
hours after the warning is
displayed.
Fault
After 72 hours the
humidifier will display a
fault and shut down.
If a replacement cylinder is
not yet available the
humidifier can be
temporarily put back into
service by turning the
humidifier off and on. The
humidifier will run for
another 72 hours.
This reset can be repeated
4 times after which the
humidifier will not run until
the cylinder is replaced and
the “Reset Cylinder”
function is entered in the
software’s service level.
Figure 41: Cylinder Spent Warning / Fault
Service LED On
+
W19 - Cylinder Spent
=
Cylinder is Spent and
must be replaced.
Request 68%
Humidifying 34 lb/hr
04/30/09 14:25:22
Security loop: Closed
Menu
Warning
?
Fault LED On
+
E19 - Cylinder Spent
=
Cylinder is Spent and
must be replaced.
Humidifier has
shut down.
Request – 68 %
Fault 34 lb/hr
04/30/09 14:25:22
Security loop: Closed
Menu
Fault
?
+ 72 Hours
Note:
Screens shown are
for the NHTC.NHPC
screens will be different
but have the same
meaning/

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nortec NHPC and is the answer not in the manual?

Nortec NHPC Specifications

General IconGeneral
BrandNortec
ModelNHPC
CategoryHumidifier
LanguageEnglish

Related product manuals