Maintenance and Servicing | 66
NHTC/PC Maintenance Checklist
Model #: _________________
Serial #: _________________ Tag: ________
Cylinder #:
Cylinder / System Check
W19 Cylinder Spent E19 Cylinder Spent
(If software displays W19 or E19 then cylinder must be replaced)
Yellow LED On with W12- Sensor On Warning.
(If Yellow LED is On with W12 and cylinder is not new then cylinder will have to be replaced soon.)
Other warnings or Faults shown in display? No Yes
(See Troubleshooting Chapter for actions to address warnings and faults if present)
Replace Cylinder
Cylinder drained.
Disconnect open, On/Off switch to Off, water shut off valve closed, door removed.
Cylinder removed
Drain valve removed / cleaned / new O-Ring
Drain valve installed / ground wire attached.
New Cylinder Installed and hose clamps tight. New cylinder model #
(Should be same as removed cylinder)
Cylinder plug colors match cylinder dots.
Cylinder plugs snug and in good condition.
High Water Sensor plug snug and in good condition.
Electrical wiring not loose and in good condition,
Steam hoses and steam lines in good condition / No kinks in hose,
No Signs of water leaking around humidifier, steam line, condensate returns,
Door replaced, water shut off valve opened, On/Off switch to On, Disconnect Closed
“Reset Cylinder” in Software, (Password 0335, Service Level)
Inspected by:
Date of inspection: _______/_______/______
Company: