Part Number Legacy
Part
Number
Part Description Supported
Systems
Notes
930-9BPSU-00J
L-000
MTEF-PSR-
AC-I
NVIDIA Power-Supply Unit, 550W AC, C2P
Airflow, For SB7700, SB7800, SB7890,
SN2410, SN2700, SX6710, SN2740 ,SX1410,
SX1710 switches, Power cord included
SN2700,
SN2740,
SN2410
The Network
operating
system identifies
this module as a
460W PSU.
HAR000028 N/A Harness RS232 2M cable – DB9 to RJ-45 SN2700,
SN2740,
SN2410,
SN2010,
SN2100
--
ACC000501 N/A Power cord Type C13-C14 SN2700,
SN2740,
SN2410,
SN2010,
SN2100
--
930-9BFAN-00IJ
-000
MTEF-FANF-
A
FAN MODULE W/ P2C air flow (front to
rear)
SN2700,
SN2410
--
930-9BFAN-00IY
-000
MTEF-FANR-
A
FAN MODULE W/ C2P air flow (rear to
front)
SN2700,
SN2410
--
Thermal Threshold Definitions
Three thermal threshold definitions are measured by the Spectrum ASICs, and impact the overall
switch system operation state as follows:
Warning– 105°C: On managed systems only: When the ASIC device crosses the 100°C
threshold, a Warning Threshold message will be issued by the management software,
indicating to system administration that the ASIC has crossed the Warning threshold. Note
that this temperature threshold does not require nor lead to any action by hardware (such as
switch shutdown).
Critical– 120°C: When the ASIC device crosses this temperature, the switch firmware will
automatically shut down the device.
Emergency– 130°C: In case the firmware fails to shut down the ASIC device upon crossing its
Critical threshold, the device will auto-shutdown upon crossing the Emergency (130°C)
threshold.
For thermal threshold definitions in Cumulus Linux, seeConfiguring Net-SNMPEvent Notification
Trapsin theCumulus Networks Help Center.