12.1 A: INITIALIZATION
508 SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
12.1 A: INITIALIZATION
The parameter group A: INITIALIZATION sets the operating environment and operating conditions for the drive.
◆ A1: INITIALIZATION
A1 parameters set the operating environment and operating conditions for the drive. For example, these
parameters set the keypad language, the control method, and the parameter access level for the drive.
■ A1-00 Language Selection
No.
(Hex.)
Name Description
Default
(Range)
A1-00
(0100)
RUN
Language Selection
Sets the language for the LCD keypad.
0
(0 - 12)
Note:
When you initialize the drive with parameter A1-03 [Init Parameters], the drive will not reset this parameter.
0 : English
1 : Japanese
2 : German
3 : French
4 : Italian
5 : Spanish
6 : Portuguese
7 : Chinese
8 : Czech
9 : Russian
10 : Turkish
11 : Polish
12 : Greek
■ A1-01 Access Level
No.
(Hex.)
Name Description
Default
(Range)
A1-01
(0101)
RUN
Access Level
Sets user access to parameters. The access level controls which parameters the keypad will
display, and which parameters the user can set.
2
(0 - 3)
0 : Monitor only
Access to A1-00, A1-01, A1-04 [Password Input], and the U: MONITORS.
1 : Manual Setup
Access to A1-00, A1-01, A1-04, A2-01 to A2-32 [MAN1 Param1 to MAN3 Param12], and the U: MONITORS.
2 : Standard Parameters
Access to all parameters, but not Expert Mode parameters.
3 : Expert Parameters
Access to all parameters including Expert Mode parameters.
Table 12.1 shows which keypad screens are available for each A1-01 settings.