4. The divider ratios for all steps are calculated and set in a table.
Step
Target (step) speed Divider ratio
1 MIN
2 MIN +
∆υ
3 MIN + 2∆υ
L MAX
5. Example
Start speed 0 (pps)
Maximum value of speed data Nos. 1 to 15 20000 (pps)
Acceleration 100 (pps/1ms)
Deceleration 100 (pps/1ms)
∆υ
= 40000/100 = 400
V = 20000 x 2 = 40000
L = (V/R) = (40000/100) = 100
44
4
8
12
192
196
200
204 388 396
392 400
t (Time)
ms
V (Speed)
400
4 ms
R = 400= 100
4
40000
39600
39200
38800
20400
20000
19600
19200
1600
1200
800
400
pps
The time required between START command bit recognition and the begin-
ning of pulse output is 0.1 second or less.
Only about 10 ms is required to begin execution of positioning actions with
“single” completion codes.
The time required between CHANGE SPEED or STOP command bit recogni-
tion and the beginning of execution is at least 4 ms.
START Activation Time
External Interrupt
Response Time
DM Area Allocation Section 3–7

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC C200H-NC112 and is the answer not in the manual?

Omron SYSMAC C200H-NC112 Specifications

General IconGeneral
BrandOmron
ModelSYSMAC C200H-NC112
CategoryControl Unit
LanguageEnglish

Related product manuals