Operation panel
38
2-4 Test mode
Operation panel
Setting dial
Turn
clockwise
Increase
Turn
counterclockwise
Decrease
Press
Set
How to read the marks
I/O test Input signal
Output signal
OUT0
Output status
Output status
Output status
Output signal
OUT1
Output status
Press
Press
Press
Top screen of test mode
Press
Press
Electromagnetic
brake test
Holding the
electromagnetic
brake
Press
Press
Press
Press
Press
Press
External voltage
To input signal
Press
Press
Releasing the
electromagnetic
brake
Press
Press
Press
Only drivers for electromagnetic brake motor
In the lower level except the top screen,
press
to return to the previous level.
When pressing the setting dial while operating a motor
The screen cannot move from the top screen of the test mode to the I/O test screen or electromagnetic brake test screen during
operation.
An error occurs even when the setting dial is pressed, and
is displayed.
Be sure to stop the motor operation before pressing the setting dial.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oriental motor BLE2D120-A and is the answer not in the manual?

Oriental motor BLE2D120-A Specifications

General IconGeneral
BrandOriental motor
ModelBLE2D120-A
CategoryEngine
LanguageEnglish

Related product manuals