EasyManuals Logo
Home>Panasonic>Air Conditioner>CS-E7NKEW

Panasonic CS-E7NKEW User Manual

Panasonic CS-E7NKEW
189 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #106 background imageLoading...
Page #106 background image
106
16.4.9 H28 (Outdoor Pipe Temperature Sensor Abnormality)
Malfunction Decision Conditions
During startup and operation of cooling and heating, the temperatures detected by the outdoor pipe temperature
sensor are used to determine sensor errors.
Malfunction Caused
Faulty connector connection.
Faulty sensor.
Faulty PCB.
Troubleshooting

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-E7NKEW and is the answer not in the manual?

Panasonic CS-E7NKEW Specifications

General IconGeneral
Indoor unit typeWall-mountable
Indoor units quantity1
Indoor unit dimensions (WxDxH)870 x 214 x 290 mm
TimerYes
Built-in displayNo
Cooling capacity (max)- BTU/h
Air conditioner functionscooling, heating
Cooling capacity in watts (max)2050 W
Heating capacity in watts (max)2800 W
Cooling energy efficiency (EER, W/W)4.36
Heating energy efficiency (COP, W/W)4.41
Outdoor units quantity0
Noise level (low speed)20 dB
Noise level (high speed)37 dB
Noise level (medium speed)24 dB
Power requirementsAC 230 V

Related product manuals