74
12.10 Indication Panel
LED POWER TIMER POWERFUL/QUIET nanoe-G ECONAVI AUTO COMFORT
Color Green Orange Orange Blue Green Green
Light ON Operation ON Timer Setting ON
POWERFUL/QUIET
Mode ON
nanoe-G
ON
ECONAVI ON
AUTO COMFORT
ON
Light OFF Operation OFF Timer Setting OFF
POWERFUL/QUIET
Mode OFF
nanoe-G
OFF
ECONAVI OFF
AUTO COMFORT
OFF
Note:
If POWER LED is blinking, the possible operation of the unit are Hot Start, during Deice operation, operation
mode judgment, or ON timer sampling.
If Timer LED is blinking, there is an abnormality operation occurs.
12.11 nanoe-G Operation
This operation provides clean air by producing great amount of negative ions and distribute through the
discharge airflow to capture or deactivate molds, bacteria or viruses.
nanoe-G operation start condition
o During unit running at any operation mode, if nanoe-G operation is activated, combination operation
(operation mode + nanoe-G operation) starts.
o During unit is OFF, if nanoe-G operation is activated, nanoe-G individual operation starts.
nanoe-G operation stop condition
o When OFF/ON button is pressed to stop the operation.
o When nanoe-G button is pressed.
o When OFF Timer activates.
nanoe-G operation pause condition
o When indoor fan stop (during deice, odor cut control, thermostat off, etc.). nanoe-G operation resume after
indoor fan restarts.
o When indoor intake temperature ≥ 40°C. nanoe-G operation resume after indoor intake temperature ≤ 40°C
continuously for 30 minutes.
Indoor fan control
o During any operation mode combines with nanoe-G operation, fan speed follows respective operation mode.
However, nanoe-G system enabled when fan speed ≥ 500rpm to ensure proper negative ion distribution,
nanoe-G system disabled when fan speed < 500 rpm.
o During nanoe-G individual operation, only Auto Fan Speed and no Powerful operation is allowed. Even if Fan
Speed button is pressed, no signal is sent to the unit and no change on remote control display. Auto Fan
Speed for nanoe-G operation changes from SHi to Hi after 4 hours of operation.
Airflow direction control
o During any operation mode combines with nanoe-G operation, airflow direction follows respective operation
mode.
o During nanoe-G individual operation, only Auto Air Swing is allowed. Even if Air Swing button is pressed, no
signal is sent to the unit and no change on remote control display.
Timer control
o When ON Timer activates when unit stops, previous operation resumes and restored last saved nanoe-G
operation status.
o When ON Timer activates during any operation, no change on current operation.
o When OFF Timer activates during any operation, all operation stops and the latest nanoe-G operation status
is saved.
Indicator
o When nanoe-G starts, nanoe-G indicator ON.