- 23 –
18-06-08 PVD3668_GB_GVM_June_2018
3.2.4. High Voltage Associations with Liquid Cooling
GVM with input coolant at 65°C – Characteristics given for an optimal inverter/motor association
Motor
Battery
DC
Voltage
Supply
Rated
Torque
Mn (N.m)
Rated
Power
Pn
(kW)
Rated
Current
In
(Arms)
Rated
Speed
Nn
(rpm)
Peak
Torque
Mmax
(Nm)
Peak
power
Pp
(kW)
Peak
Current
Ip
(Arms)
Max.
Speed
Nmax
(rpm)
Pure
Water
Flow
(l/min)
Efficiency
at Rated
Power
(%)
GVM142 - Three-phased - Liquid cooled at 65°C
GVM142-050-XQW
320
17.6
12.3
39
6700
40
17.3
110.4
9500
1.21
93.1
GVM142-050-DRW
400
17.6
12.2
30.7
6600
40
17.1
87.0
9500
1.2
93.1
GVM142-050-HRW
480
17.6
11.9
25.1
6470
40
16.8
71.0
9500
1.2
93
GVM142-050-RRW
640
17.7
11.5
18.1
6220
40
16.1
51.1
8890
1.16
92.9
GVM142-075-NQW
320
27.6
18.5
58.8
6400
62
25.9
167.8
9500
1.74
93.4
GVM142-075-SQW
400
27.5
19.3
48.9
6700
62
27.2
140.1
9500
1.79
93.6
GVM142-075-XQW
480
27.5
19
39.9
6600
62
26.6
114.2
9500
1.78
93.5
GVM142-075-ERW
640
27.6
18.7
29.5
6500
62
26.3
84.4
9500
1.76
93.4
GVM142-100-EQW
320
37
26.3
83.1
6800
85
37.2
247.7
9500
2.36
93.9
GVM142-100-NQW
400
37.6
23.6
59.4
6000
85
32.8
174.3
9000
2.18
93.6
GVM142-100-SQW
480
37.6
23.6
49.6
6000
85
32.9
145.6
9000
2.18
93.8
GVM142-100-ZQW
640
37.5
23.8
37.2
6050
85
33.1
109.5
8570
2.19
94
GVM210 - Three-phased - Liquid cooled at 65°C
GVM210-050-QQW
320
36.9
21.2
66.4
5490
82
32.9
165.3
8000
1.51
95.3
GVM210-050-VQW
400
36.8
22.1
55
5740
82
34.4
137.6
8000
1.56
95.2
GVM210-050-VQW
480
36
26.2
54.1
6940
82
41.4
137.5
8000
1.85
95.1
GVM210-050-FRW
640
36
26
40
6890
82
40.9
101.7
8000
1.83
95.1
GVM210-100-SPW
320
78.6
53.5
166
6500
173
82.3
418.1
8000
3.45
95.7
GVM210-100-XPW
400
78.6
53.5
133
6500
173
83.2
336.1
8000
3.45
95.9
GVM210-100-DQW
480
79.1
52.2
108
6300
173
81.0
272.1
8000
3.35
95.9
GVM210-100-MQW
640
78.3
54.1
83.6
6600
173
84.3
211.6
8000
3.5
95.6
GVM210-150-DPW
320
115
84.1
262
7000
262
136.5
687.9
8000
5.34
95.9
GVM210-150-JPW
400
114
84.9
210
7100
262
138.1
554.7
8000
5.41
95.8
GVM210-150-SPW
480
118
80
163
6500
262
125.6
419.5
8000
4.99
95.9
GVM210-150-ZPW
640
118
80
122
6500
262
125.1
312.7
8000
4.99
96
GVM210-200-DPW
320
164
89.4
278
5200
352
137.1
692.1
7800
5.35
96.2
GVM210-200-DPW
400
152
105
259
6610
352
172.2
692.0
8000
6.49
96
GVM210-200-JPW
480
154
103
211
6410
352
167.0
558.1
8000
6.32
96
GVM210-200-SPW
640
153
104
159
6510
352
168.8
421.9
8000
6.41
96
GVM210-300-DPW
320
262
93.2
293
3400
530
136.9
692.2
5100
5.85
96.2
GVM210-300-DPW
400
251
113
281
4300
530
172.1
692.1
6450
6.66
96.3
GVM210-300-DPW
480
238
132
267
5300
530
207.6
692.0
7950
7.68
96.3
GVM210-300-DPW
640
205
155
232
7220
530
277.8
691.9
8000
9.83
95.8
GVM210-400-DPW
320
358
93.6
299
2500
710
136.0
695.3
3750
6.59
95.8
GVM210-400-DPW
400
348
116
290
3190
710
172.0
695.2
4800
7.27
96.2
GVM210-400-DPW
480
336
137
281
3900
710
207.6
695.1
5850
8.03
96.4
GVM210-400-DPW
640
306
170
257
5310
710
278.6
695.0
7950
9.76
96.3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker GVM Series and is the answer not in the manual?

Parker GVM Series Specifications

General IconGeneral
BrandParker
ModelGVM Series
CategoryEngine
LanguageEnglish

Related product manuals