EasyManuals Logo
Home>Parker>Engine>GVM Series

Parker GVM Series User Manual

Parker GVM Series
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #69 background imageLoading...
Page #69 background image
- 69
18-06-08 PVD3668_GB_GVM_June_2018
Conversion Awg/kcmil/mm² :
Awg
kcmil
mm²
500
253
400
203
350
177
300
152
250
127
0000 (4/0)
212
107
000 (3/0)
168
85
00 (2/0)
133
67.4
0 (1/0)
106
53.5
1
83.7
42.4
2
66.4
33.6
3
52.6
26.7
4
41.7
21.2
5
33.1
16.8
6
26.3
13.3
7
20.8
10.5
8
16.5
8.37
9
13.1
6.63
10
10.4
5.26
11
8.23
4.17
12
6.53
3.31
14
4.10
2.08
16
2.58
1.31
18
1.62
0.82
20
1.03
0.52
22
0.63
0.32
24
0.39
0.20
26
0.26
0.13
3.8.2. Motor cable length
For motors windings which present low inductance values or low resistance values, the own
cable inductance, respectively own resistance, in case of large cable length can greatly
reduce the maximum speed of the motor. Please contact PARKER for further information.
Caution: It might be necessary to fit a filter at the servo-drive output if the
length of the cable exceeds 25 m. Consult us.