In case of failure with the key set to the «ON» position of the «UP» and «DOWN» buttons, and if the
icon on the digital display flashes, it is necessary to reset the adjustment system.
Proceed as follows:
- position the vehicle on centre stand.
- set the switch to «OFF» position.
- simultaneously hold down the «UP» and «DOWN» buttons and set the switch to «ON» position.
- The system proceeds to the resetting by performing a complete travel on the shock absorber, first in
extension then in compression, by repositioning it to the lower stop and normalizing the indication on
the digital display.
- set the switch to «OFF» position.
Battery installation
VRLA battery (valve-regulated lead-acid battery) Maintenance Free (MF)
WARNING
BATTERY ELECTROLYTE IS TOXIC AND IT MAY CAUSE SERIOUS BURNS. IT CONTAINS SUL-
PHURIC ACID. AVOID CONTACT WITH YOUR EYES, SKIN AND CLOTHING. IN CASE OF CON-
TACT WITH YOUR EYES OR SKIN, RINSE WITH ABUNDANT WATER FOR ABOUT 15 MINUTES
AND SEEK IMMEDIATE MEDICAL ATTENTION.
IN THE EVENT OF ACCIDENTAL INGESTION OF THE LIQUID, IMMEDIATELY DRINK LARGE
QUANTITIES OF WATER OR MILK. MAGNESIUM MILK, BATTERED EGG OR VEGETABLE OIL.
SEEK IMMEDIATE MEDICAL ATTENTION.
BATTERIES PRODUCE EXPLOSIVE GASES; KEEP CLEAR OF NAKED FLAMES, SPARKS OR
CIGARETTES; VENTILATE THE AREA WHEN RECHARGING INDOORS.
ALWAYS PROTECT YOUR EYES WHEN WORKING CLOSE TO BATTERIES.
KEEP OUT OF THE REACH OF CHILDREN
1) Battery preparation
Position the battery on a flat surface. Remove the
adhesive sheet closing cells and proceed as quick-
ly as possible to run the subsequent activation
phases.
2) Electrolyte preparation.
Remove the container of the electrolyte from the
pack. Remove and preserve cover strips from the
container, in fact, the strip will later be used as a
closing cover.
Note: Do not pierce the sealing of the container or
the container itself because inside there is sulphu-
ric acid.
MSS X10 500ie Executive Electrical system