15 EN
• With the controller not connected to power supply.
The memory card is equipped with an internal battery with an
autonomy of about 1000 uses (2032 button battery, replaceable).
Insert the memory card and press the programming buttons.
When writing the parameters, the led turns red and on completing the
procedure it changes to green. It is possible to repeat the procedure
without any particular attention.
1
If on activation the controller does not display it means no data have been
saved on the memory card, but it is possible to update values.
7.8 Loading default values
Press Display Do
1
SET
for 3 second
Display 1 shows
with the 1
st
digit
ashing, while display 2
shows
.
2
or
Change the ashing
digit and move to the
next one using the
key.
Enter password:
.
3
SET
to con rm
Display 1 shows the
rst parameter and
display 2 shows the
value.
Updating Memory Card
To update the memory card values, follow the
procedure described in the rst method, setting
display 2 to
so as not to load the parameters
on controller
1
.
Enter con guration and change at least one
parameter.
Exit con guration. Changes are saved automatically.
WARNING