Page 30
Volume (UoL) Menu
P600 Vessel Shape
This parameter determines which vessel shape is used when utilising
“Volume Conversion”.
The choices are as shown in the table below, along with the dimensions that
are required to be entered (P601-P603).
Vessel Shape P600 Value
Dimensions
Required
P600=0 Cylindrical
Flat base (Default)
Cylinder diameter
P600=1=Rectangular
Flat base
Width and Breadth
P600=2 Cylindrical
Cone base
Cylinder diameter
and height of
bottom
P600=3 Rectangular
Pyramid base
Width and Breadth
of rectangular
section and height
of bottom
P600=4 Cylindrical
Parabola base
Cylinder diameter
and height of
bottom
P600=5 Cylindrical
Half-sphere base
Cylinder Diameter