Section I - General Information
Introduction
Thank you for purchasing a QCS emulsion
separator. Please read these instructions
carefully before installing your QCS
unit and putting it into service. Trouble
free functioning of QCS emulsion
separators - and thus reliable condensate
treatment - can only be guaranteed if the
recommendations and conditions stated
here are adhered to.
Wastewater destined for indirect
discharge must not exceed a hydrocarbon
concentration of 20 ppm.
Please note that the national legal limit
values for indirect discharge may vary
regionally.
Media / ambient temperature:
+41...+140 °F
QCS separators are suitable for
stationary application only.
♦
♦
Applications
QCS separators are designed for the
treatment of demulsifiable compressor
condensates in compliance with legal
requirements. Your local “lower-level water
authority” should be notified about the
operation of an oil/water separator.
Caution
Oil-contaminated condensate.
Oil-contaminated condensate contains
substances that are hazardous both
to health and the environment. These
substances may cause irritation or
damage to the skin, eyes and mucous
linings. Oil-contaminated condensate
must not be allowed to get into the
sewer system, water bodies or soil.
Contaminated objects must be cleaned
or disposed of according to the legal
regulations.
Quincy Compressor-QCS High Efficiency Emulsion Separators 1