professionals.
The device is not sold to the general public and is sold only for industrial or commercial use by pro-
fessional installers.
CAUTION
CAUTION
To reduce potential radio interference to other users, the antenna type and its gain should be chosen so
To reduce potential radio interference to other users, the antenna type and its gain should be chosen so
that the equivalent isotropically radiated power (EIRP) is not more than that permitted for successful
that the equivalent isotropically radiated power (EIRP) is not more than that permitted for successful
communication.
communication.
Maximum Certified Power
ISM band radio modules may be operated at full certified power when configured with the granted an-
tenna type. Operation of a radio at power levels that exceed the equivalent EIRP of the granted configura-
tion is prohibited. See the following tables.
Table: Maximum Certified Power: FCC (United States)
Model ES1-2450R
Frequency Range
(MHz)
Total Conducted Channel
Power (dBm)
Antenna
Type
Antenna Gain
(dBi)
EIRP
(dBm)
2412-2462 26 (Average)
Omni-
directional
5 31
5150-5250 (Average)
Omni-
directional
5180-5240 23 (Average)
Omni-
directional
7 30
5725-5850 (Average)
Omni-
directional
5745-5825 25 (Average)
Omni-
directional
6 31
Model ES1-5050CS
The bands being certified for ES1-5050CS are 4.9 GHz and 5 GHz (B1 through B3).
Frequency Range
(MHz)
Total Conducted Channel
Power (dBm)
Antenna
Type
Antenna Gain
(dBi)
EIRP
(dBm)
4940-4990 (Average)
Omni-
directional
5150-5250 (Average)
Omni-
directional
5180-5240 23 (Average)
Omni-
directional
7 30
5250-5350 (Average)
Omni-
directional
5470-5725 (Average)
Omni-
directional
5725-5850 (Average)
Omni-
directional
Table: Maximum Certified Power: IC (Canada)