34 ST60 Tridata Instrument Owners Manual
4.3 Intermediate calibration
Intermediate calibration enables you to:
Check the instrument software version.
Check the instrument status - either YES (master)) or NO (repeater).
You can also change the depth status, as required. This feature is par-
ticularly useful in preventing interference when using another prod-
uct (e.g. a fishfinder) that operates at 200 kHz.
Carry out a calibration run over a measured distance to ensure accu-
rate speed readings.
To start Intermediate calibration, hold down the
depth and speed keys
for approximately 4 seconds (see Intermediate calibration flow chart).
To set the instrument status:
1. Press the
depth key to select the Instrument status screen.
2. Press the
trip and reset keys simultaneously to enter the depth adjust
mode, then press either
trip or reset to set the required status, i.e.
either YES (for master operation) or NO (for repeater operation).
Note: You must not allocate more than one master depth instrument in
any system.
3. Press the trip and reset keys simultaneously again, to leave the adjust
mode.
81040_1.book Page 34 Thursday, November 7, 2002 10:21 AM

Table of Contents

Other manuals for Raymarine ST60 Tridata

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Raymarine ST60 Tridata and is the answer not in the manual?

Raymarine ST60 Tridata Specifications

General IconGeneral
BrandRaymarine
ModelST60 Tridata
CategoryMarine Equipment
LanguageEnglish

Related product manuals