EasyManuals Logo

Rheem RIDH07AVFJ User Manual

Rheem RIDH07AVFJ
328 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #262 background imageLoading...
Page #262 background image
- 254 -
OUTDOOR UNIT
ROMH24AFXZJ
12. Safety devices
*Pressure switch 2: For control device. (Refer to the wiring diagram.)
Type of protection Protection form
Model
ROMH24AFXZJ
Circuit protection
Current fuse
(Main PCB)
250 V, 5 A
250 V, 3.15 A
Current fuse
(Near the terminal)
250 V, 10 A
Fan motor protection Temperature thermistor
Activate
302 ±27 °F
(150 ±15 °C)
Fan motor stop
Reset
248 ±27 °F
(120 ±15 °C)
Fan motor restart
Compressor protection Temperature thermistor
Activate
230 ±4 °F
(110 ±2 °C)
Compressor stop
Reset
176 ±4 °F
(80 ±2 °C)
Compressor restart
Refrigerant circuit
protection
Pressure switch 1
Activate
609 ±15 PSI
(4.2 ±0.1 MPa)
Reset
464 ±22 PSI
(3.2 ±0.15 MPa)