EasyManuals Logo
Home>Rigol>Test Equipment>MSO7000 Series

Rigol MSO7000 Series User Programming Manual

Rigol MSO7000 Series
259 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #205 background imageLoading...
Page #205 background image
Chapter 2 Command System RIGOL
MSO7000/DS7000 Programming Guide 2-191
Return Format
The query returns the upper limit of the trigger level in scientific notation.
Example
:TRIGger:DELay:ALEVel 0.16 /*Sets the upper limit of the trigger level to 160 mV.*/
:TRIGger:DELay:ALEVel? /*The query returns 1.600000E-1.*/
:TRIGger:DELay:BLEVel
Syntax
:TRIGger:DELay:BLEVel <level>
:TRIGger:DELay:BLEVel?
Description
Sets or queries the lower limit of the trigger level of Delay trigger. The unit is the same
as that of the current amplitude.
Parameter
Name
Type
Range
Default
<level>
Real
(-5 × VerticalScale - OFFSet) to upper limit
0 V
Remarks
For VerticalScale, refer to the :CHANnel<n>:SCALe command; for OFFSet, refer to
the :CHANnel<n>:OFFSet command.
Return
Format
The query returns the lower limit of the trigger level in scientific notation.
Example
:TRIGger:DELay:BLEVel 0.05 /*Sets the lower limit of the trigger level to 50 mV.*/
:TRIGger:DELay:BLEVel? /*The query returns 5.000000E-2.*/

Table of Contents

Other manuals for Rigol MSO7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol MSO7000 Series and is the answer not in the manual?

Rigol MSO7000 Series Specifications

General IconGeneral
BrandRigol
ModelMSO7000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals