Roche/Hitachi cobas c 311 analyzer Record structure
Photometric Calibration Result Record
Roche Diagnostics May 2011
Host Interface Manual – Version 1.3 E-18
Photometric Calibration Result Record
cobas type (Upload)
An example in case that Chemistry Test Calibration Results Detail mode is disabled.
M|1|PCR|BMSERV|^^^714|P1|||2782^2805^2839^2860^^\6119^6577^6134^6592^^|[CR]
(1)(2)(3) (4) (5) (6) (7)(8) (9)
An example in case that Chemistry Test Calibration Results Detail mode is enabled.
M|1|PCR|BMSERV|^^^714|P1|||2782^2805^2839^2860^^\6119^6577^6134^6592^^\
(1)(2)(3) (4) (5) (6) (7)(8) (9)
^^^^^\^^^^^\^^^^^\^^^^^|649252^^649252^|24615^^10363^|1|
(10) (11) (12)
18689700^16627800^^^^|20051016144610|[CR]
(13) (14)
Comments
No
Field
No.
Field Type Max
cobas Type
(1) 1 Record Type ID ST 1 ‘M’ fixed.
(2) 2 Sequence Number NM 6 This record appears as the next layer of the Message Header Record. For one record, the
field value is ‘1’; for specifying several, sequence numbers starting from 1 are assigned
(3) 3 Record Type Sub ID ST 3 Use ‘PCR’.
(4) 4 Operator ID ST 6 ID of the operator who performed the calibration at the analyzer
(5) 5 Test Code CM 8 Format ^^^<Application Code>
Element Max Length Format
Application Code 5 NM
(6) 6 Module ID ST 4 Indicates the ID of the analytical unit (module) that performed the analysis.
Module
Description
P1 cobas c 311 analyzer Module
Non Calculate Test or Not measured test
(7) 7 Calibration Alarm NM 3 Calibration alarm.
(8) 8 SD Data Field NM 6 SD value data.
(9) 9 STD Data CM 38 Repeat Field.
Repeated from STD1 to STD6 for as many as there are. Format<Absorbance Data for the
first time>^<First time for the first one or the final absorbance data>^<Absorbance Data of the
second time>^<Second time for the first one or the final absorbance data>^<Data
Alarm>^<Prozone Value>
Detail specification is shown below;
Element
Max Length Format
<Absorbance Data for the 6 NM
first time>
<First time for the first one 6 NM
or the final absorbance data>
<Absorbance Data of the 6 NM
second time>
<Second time for the first one 6 NM
or the final absorbance data>
<Data Alarm> 3 NM
(See Table E-3 Data Alarm List.)
<Prozone Value> 6 NM
.
(10) 10
Reagent lot number
NM 8 R1 Reagent bottle sequence number
1 to 99999999
This data is sent to the host only when an option of “Chemistry Test Calibration Results
Detail” is selected.
(11) 11
Reagent bottle
number
NM 5 R1 Reagent bottle sequence number
1 to 199999
This data is sent to the host only when an option of “Chemistry Test Calibration Results
Detail” is selected.