84
4 Adjustment
4
4-9 Y Axis Load Check (Referential Time : 8 minutes)
Turn on the Power while pressing the [ ], [ ], [ ]
keys to enter the Service Mode.
Select the [LOAD] menu by pressing the [MENU] key and
press [ENTER] key.
1
CHECK MODE
LOAD CON. CARD
[ ], [ ], [ ] + POWER ON
[ENTER] key
[MENU] key
3
After setting the value, the load check starts.
The Carriage moves in the Y direction to check the load.
2
Select the [AXIS Y] in the [LOAD] menu and press [ENTER]
key. Then, Carriage moves to the Limit Position.
Enter the value 500 and press the [ENTER] key.
AXIS X Y Z S
[ENTER] key
AXIS X Y Z S
VALUE 500
[ENTER] key
AXIS X Y Z S
VALUE 500 OK