MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
5
Interlock function
It has an interlock function to realize only one valve in regeneration
but the others are in service while several valves are in parallel
connection or in series connection in the system. In multi-steps
treatment systems such as RO pre-treatment, when several valves are
in series, there is only one valve in regeneration or washing to ensure
there is water passing all the times while different valves in regeneration
or washing. (Application refer to Figure 3-9)
Signal Output (F116Q as example)
There is a signal output connector on the main control board. It is for
controlling external wiring (Refer to figures from Figure3-1 to Figure
3-8).
There are two kinds of output modes: b-01 Mode: Turn on when
regeneration started and shut off at the end of regeneration; b-02 Mode:
Signal available only at intervals of regeneration cycles and in service.
User can set the maximum interval regeneration days (Only
for F67Q3/ F68Q3/F69Q3/F71Q3/F116Q3/F117Q3)
In the situation of service reaching the setting days but the volume
not yet, it could enter into regeneration process forcibly when current
time is the same as regeneration time.
All parameters can be modified
According to the water quality and usage, the parameters in the