Operating Instructions
LMS1xx Laser Measurement Sensors
Product description
8012471/ZN27/2017-06-09 © SICK AG · Germany · All rights reserved · Subject to change without notice 41
Chapter 3
3.9.1 Evaluation cases
An evaluation case defines which output field is evaluated in which way and on which output
it acts. You can configure up to ten evaluation cases, all configured evaluation cases are
active simultaneously.
For each evaluation case you configure in SOPAS ET:
inputs that activate an evaluation case, if necessary
the evaluation strategy
the evaluation field
the output on which the evaluation case acts
the response time of the output
PROJECT TRee, LMS…, PARAMETER, EVALUATION CASES.
Inputs
If the evaluation case is not to be permanently active, then you can configure an input
combination to activate the evaluation case.
Wichtig An input combination can also be defined for several evaluation cases, e.g. two evaluation
cases will then be active simultaneously.
LMS12x/LMS13x/LMS14x Security and LMC12x/LMC13x VdS (object protection)
You will find the input conditions for these devices in the document ”Technical Information
(installer instructions VdS)”, part no.: 8013749, issue in English.
Please see section 1.5 “Further information” on page 9.
Input 1 Input 2 Evaluation case
Active high Active high Evaluation case 1
Active high Active low Evaluation case 2
Active low Active high Evaluation case 3
Active low Active low Evaluation case 4
Tab. 11: Input combination examples LMS10x/LMS11x/LMS15x