10 Technical specifications
10.1 Data sheet LMS1xx/LMC1xx laser measurement sensor
Minimum Typical Maximum
Functional data
Scan angle 270°
Scanning frequency 25 Hz 50 Hz
Remission 3 % Several 1,000 %
1)
(reflectors)
Angular resolution
With 25 Hz 0.25° 0.5°
With 50 Hz 0.5°
Measuring error 1. Reflected pulse
2)
– All variants except LMS14x Security
Systematic error 30 mm 50 mm
Temperature drift 0 mm/°C 0.32 mm/°C
Statistical error (1 ) 12 mm 20 mm
Measuring error 1. Reflected pulse
3)
– LMS14x Security
Systematic error 30 mm 50 mm
Temperature drift 0 mm/°C 0.32 mm/°C
Statistical error (1 ) (0.5 m... 10 m) 12 mm
Statistical error (1 ) (10 m ... 20 m) 20 mm
Statistical error (1 ) (20 m ... 40 m) 35 mm 50 mm
Immunity to external light 40 klx
Evenness of the scan field (25 Hz)
Cone 0.5° 1°
Inclination 1° 2°
Distance from mirror axis of rotation (zero point on the X and Y axis) to the rear
of the device
55 mm
Distance between centre of the scan plane and the bottom edge of the housing 116 mm
Distance measuring range (operating range)
LMS10x/LMS11x
LMS12x/LMS13x/LMS173/LMS182 Security
LMC12x/LMC13x VdS
0.5 m 20 m
LMS14x Security 0.5 m 40 m
LMS15x 0.5 m 50 m
Hardware blanking window 0 m 15 m
Step width 1 m
Power-up delay 60 s
Of a configured device 15 s
Configurable restart after 2 s 60 s
Numbers of evaluation fields
LMS10x/LMS11x/LMS15x
LMS12x/LMS13x/LMS173/LMS182 Security
LMC12x/LMC13x VdS
10
LMS14x Core Security 4
LMS14x Prime Security 10
Tab. 38: Data sheet LMS1xx/LMC1xx