Page #62 background image
Mounting
62 © SICK AG · Germany · All rights reserved · Subject to change without notice 8012471/ZN27/2017-06-09
Operating Instructions
LMS1xx Laser Measurement Sensors
Chapter 5
5.3.5 Using multiple LMS1xx
Risk of interference on the LMS1xx!
Sources with a wavelength of 905 nm may cause interference if they act directly on the
LMS1xx.
The LMS1xx is so designed that mutual interference between several LMS1xx is unlikely. To
completely exclude erroneous switching, we recommend mounting the laser measurement
sensors as shown in the following examples.
Use mounting kits 1 to 3 to adjust the LMS1xx to different angles.
Correct placement of several LMS1xx
Arrange or shield several LMS1xx such that the laser beam cannot be received by a different
LMS1xx.
Fig. 38: Placement of two LMS1xx opposed to each other
Fig. 39: Crosswise placement of two LMS1xx
Fig. 40: Placement of two LMS1xx with parallel offset