Chapter 2 Technical Information
TiM55x/56x/57x ranging laser scanner
6 © SICK AG · Germany · All rights reserved · Subject to change without notice 8015883/YZK8/2016-07-07
Operating principle of the TiM5xx
2 Operating principle of the TiM5xx
2.1 Measurement principle
The TiM5xx is an opto-electronic laser scanner that electro-sensitively scans the perimeter
of its surroundings at a single plane with the aid of laser beams. The TiM5xx measures its
surroundings using two-dimensional polar coordinates based on its measurement origin.
This is marked on the hood in the centre using a circular indentation. If a laser beam hits
an object, its position in terms of distance and direction is determined.
Scanning is performed across a 270° sector. The maximum range of the TiM5xx is max.
10 m (TiM55x/TiM56x) and 25 m (TiM57x) on light, natural surfaces with an object reflec-
tivity > 50 % (e.g. a white house wall).
The scanning range is 8 m in the case of dark surfaces with remission of > 10%.
2.2 Distance measurement
The TiM5xx emits pulsed laser beams using a laser diode. If one of these laser pulses hits
an object or a person, this is reflected at its surface. The reflection is detected in the
TiM5xx's receiver by a photodiode. The TiM5xx uses HDDM technology (High Definition
Distance Measurement), a SICK own-development. Using this measurement method, a
measured value is formed by the average value for several individual pulses. The TiM5xx
calculates the distance to the object from the transit time required by the light from emis-
sion of the beam to receipt of the reflection. This principle of "time-of-flight measurement"
is used by radar systems in a similar manner.
2.3 Direction measurement
The emitted laser beams are deflected by the TiM5xx using a rotating mirror and its sur-
roundings scanned in a circular form. The measurements are triggered internally at regular
angle increments using an angular encoder. One complete rotation represents one measur-
ing process (scan).
The TiM5xx works at a scanning frequency of 15 Hz, i.e. it performs 15 measuring processes
per second and makes the measurement results continuously available in real time via an
Ethernet interface.

Other manuals for SICK TiM55 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK TiM55 Series and is the answer not in the manual?

SICK TiM55 Series Specifications

General IconGeneral
BrandSICK
ModelTiM55 Series
CategoryAccessories
LanguageEnglish

Related product manuals