Chapter 2 Technical Information
TiM55x/56x/57x ranging laser scanner
8 © SICK AG · Germany · All rights reserved · Subject to change without notice 8015883/YZK8/2016-07-07
Operating principle of the TiM5xx
TiM56x
TiM57x
0
40
80
120
160
200
240
01 23 5 7468
Range (m)
Spot diameter (mm)
Spot diameter of a submeasuring point.
Divergence 9.5 mrad, spot diameter on the front screen 6 mm
Elongation of the 84 overlayed submeasuring points in direction
of deflection at angle step 0.3°.
Divergence 15 mrad, spot diameter on the front screen 6.5 mm
910
0
80
160
240
320
400
0 2 4 6 10 1481216
Range (m)
Spot diameter (mm)
Spot diameter of a submeasuring point.
Divergence 9.6 mrad, spot diameter on the front screen 6 mm
Elongation of the 84 overlayed submeasuring points in direction
of deflection at angle step 0.3°.
Divergence 15 mrad, spot diameter on the front screen 6.5 mm
18 20 22 24 26