WARNING
Potential Arc Hazard
Arcing can result in damage to property, serious injury and even death.
The equipment has not been tested and rated for arc flash protection.
Avoiding arc hazard risks is dependent upon proper installation and maintenance.
Incorrectly applied equipment, incorrectly selected, connected or unconnected cables, or
the presence of foreign materials can cause arcing in the equipment.
Follow all applicable precautionary rules and guidelines as used in working with medium
voltage equipment.
The equipment may be used only:
for the applications defined as suitable in the technical description.
in combination with equipment and components supplied by other manufacturers which
have been approved and recommended by Siemens.
Additional safety precautions and warnings appear throughout this manual. These important
messages should be followed to reduce the risk of personal injury or equipment damage.
WARNING
Obey Rules to Avoid Risk of Death
Always comply with local codes and requirements if disposal of failed components is
necessary.
Always ensure the use of an even and flat truck bed to transport the VFD system. Before
unloading, be sure that the concrete pad is level for storage and permanent positioning.
Always confirm proper tonnage ratings of cranes, cables, and hooks when lifting the VFD
system. Dropping the cabinet or lowering it too quickly could damage the unit.
Never disconnect control power while medium voltage is energized. This could cause
severe system overheating and/or damage.
Never store flammable material in, on, or near the drive enclosure. This includes
equipment drawings and manuals.
Never use fork trucks to lift cabinets that are not equipped with lifting tubes. Be sure that
the fork truck tines fit the lifting tubes properly and are the appropriate length.
Safety Notes
2.4 Safety Information and Warnings
SINAMICS PERFECT HARMONY GH180 6SR41 manufactured in NMA Nuernberg, Germany
Operating Instructions Rev.201706301306 25

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens GH180 and is the answer not in the manual?

Siemens GH180 Specifications

General IconGeneral
BrandSiemens
ModelGH180
CategoryPower Tool
LanguageEnglish

Related product manuals