Procedure
1. Push the lifting rods through the holes.
2. Place the sling ropes on the ends of the lifting rods and secure the ends of the lifting rods
using the splint.
3. To lift the transport unit, use single sling ropes or two ropes with a cross stitch. Attach the
crane rope to the ends of the lifting rods and then lift the cabinet. Avoid displacing the center
of gravity or distorting the cabinet. When suspended, the cabinet must be parallel to the
ground.
4.5.2 Transporting the cabinet units
When the transport units are transported with a crane, note that force is applied via the
supporting frame of the cabinet. The supporting frame remains on the unit. The device is
mounted at the installation site via the supporting frame.
WARNING
Inadequately dimensioned lifting rods
Inadequately dimensioned lifting rods are liable to bend or break. The converter could drop
off the crane as a result, causing death, serious injury, or material damage.
Use suitable lifting rods for transportation. The weight of the converter is indicated on the type
plate.
Preparing for Use
4.5 Transportation
SINAMICS PERFECT HARMONY GH180 6SR41 manufactured in NMA Nuernberg, Germany
66 Operating Instructions Rev.201706301306