Functions
Additional functions
4
48 | 186
A6V11545892_en--_e
Functions (parameters)
Description
Standalone
RDG
KNX
Sensors and changeover functions [ 49]
Heating/cooling changeover via bus
(KNX)
Central control of heating / cooling via bus
2..KN
Automatic heating/cooling changeover
via changeover sensor
Changeover switch (P150, P153, P155)
Auto changeover on each equipment
2..
Manual heating/cooling changeover
(P001)
Heating / cooling controlled manually by user
(via HMI)
2..
External/return air temperature sensor
(P150, P153, P155)
Temperature measurement with external
sensors
2..
Presence detector [ 50]
Standard presence mode (P150 / P153 /
P155)
Switch operating mode locally or via bus
2..
Hotel presence mode (P150 / P153 /
P155)
Switch operating mode locally or via bus
2..
Output functions [ 52]
Purge function (P251)
To ensure correct acquisition of the water
temperature
2..
Minimum output On/Off time (P212,
P213)
To protect the HVAC equipment, for example,
the compressor and reduce wear and tear
2..
Swap outputs for 2-pipe and 2-stage
applications (P254)
To optimize the use of heating/cooling energy in
mixed systems
2..
Floor heating/cooling (P350)
Application without fan control
2..
Qx relay switching function (P400, P401,
P402)
Control external equipment based on function
status (Heating/cooling demand, operating
mode, sequence, humidity, …)
2..
Monitoring and limiting functions [ 54]
Floor temperature limitation function
(P252)
For user Comfort and protect the floor
2..
Supply air temperature limitation (P063,
P064)
To increase the comfort, by avoiding too warm
or too cold air in the room
2..
Flow limitation in heating and cooling for
PICV (P260, P261 (only RDG264KN:
P256))
To balance heating and cooling systems and
avoid hydraulic problems caused by different
flow rates
2..
Dewpoint monitoring
Fault state "condensation" (P150, P153,
P155 = 4)
To prevent condensation damages in the
building
2..
Valve kick/exercising (P250)
To prevent valve freezing after extended
inactivity
2..
Return flow temperature control (P061,
P062)
To save energy by adjusting flow speed in
district heating systems
2..
User operation / Indication [ 57]
Button lock (P028)
To limit access to unauthorized people
2..
Green leaf (P110, P111)
Indication about energy efficient
2..KN
Set time / date
To set the time of day (AM/PM, hours and
minutes) and date (weekday, month and year)
2..
Set Away (holiday mode)
To set a holiday period
2..

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RDG20 KN Series and is the answer not in the manual?

Siemens RDG20 KN Series Specifications

General IconGeneral
BrandSiemens
ModelRDG20 KN Series
CategoryThermostat
LanguageEnglish

Related product manuals