Chapter 4
Technical Specifications
RUGGEDCOM RX1500
Installation Guide
42 Fast Ethernet (100 Mbps) Optical Specifications
Mode
Connector
Type
Cable
Type (μm)
Tx λ (typ.)
(nm)
Tx min.
(dBm)
Tx max.
(dBm)
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(typ.) (km)
Power
Budget
(dB)
SM ST 9/125 1300 -15 -8 -32 -3 20 17
SM SC 9/125 1300 -15 -8 -31 -7 20 16
SM LC 9/125 1300 -15 -8 -34 -7 20 19
SM LC 9/125 1300 -15 -8 -34 -7 20 19
SM SC 9/125 1300 -5 0 -34 -3 50 29
SM LC 9/125 1300 -5 0 -35 3 50 30
SM LC 9/125 1300 -5 0 -35 3 50 30
SM SC 9/125 1300 0 5 -37 0 90 37
SM LC 9/125 1300 0 5 -37 0 90 37
SM LC 9/125 1300 0 5 -37 0 90 37
MTRJ 62.5/125 -19 12
MM
LC 50/125
1300
-22.5
-14 -31 -14 2
8.5
MTRJ 62.5/125 -19 12
MM
LC 50/125
1300
-22.5
-14 -31 -14 2
8.5
SFP Fast Ethernet Transceivers
Mode
Connector
Type
Cable
Type (μm)
Tx λ (typ.)
(nm)
Tx min
(dBm)
Tx max
(dBm)
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(typ.) (km)
Power
Budget
(dB)
62.5/125 -20 11
MM LC
50/125
1310
-23.5
-14 -31 -14 2
7.5
62.5/125 -20 11
MM LC
50/125
1310
-23.5
-14 -31 -14 2
7.5
SM LC 9/125 1300 -15 -8 -31 -8 15 16
SM LC 9/125 1300 -15 -8 -31 -8 15 16
SM LC 9/125 1300 -5 0 -34 0 40 29
SM LC 9/125 1300 -5 0 -34 0 40 29
SM LC 9/125 1550 -5 0 -34 -10 80 29
SM LC 9/125 1550 -5 0 -34 -10 80 29

Table of Contents

Other manuals for Siemens RUGGEDCOM RX1512

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM RX1512 and is the answer not in the manual?

Siemens RUGGEDCOM RX1512 Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM RX1512
CategorySwitch
LanguageEnglish

Related product manuals