Technical data
8.3 Technical specifications of the SCALANCE XR528-6M
SCALANCE XR-500
90 Operating Instructions, 05/2017, A5E03275845-11
Ambient temperature
1)
Operation without filter pad and with-
out SFP+ LH transceiver up to 2000 m
0 °C to +60 °C
When operating as of 2000 m The maximum ambient temperature is
Design, dimensions and weight
Weight (basic device without media
7.2 kg
Degree of protection (with closed ser-
IP20
Dimensions without brackets for
19" rack mounting (W x H x D)
446 x 88 x 305 mm (2 height units)
Installation options
• 19" rack mounting
• Desktop operation
• Four-point mounting
Design of the mounting bracket for use on ships
Dimensions without brackets for
19" rack mounting (W x H x D)
60 x 87.1 x 18.3 mm (2 height units)
Mean time between failure (MTBF)
• Basic device without media mod-
ules
• at 40 °C ambient temperature
> 17.1 years
1)
Depending on which components you use, the maximum ambient temperature can
change, see section "Permitted ambient temperature (Page 19)".
Note
ISO tolerance and punching burr
For dimensions without tolerance details, the general tolerances "medium" acc. to DIN ISO
2768 apply. No punching burrs are permitted.