Commissioning the device
4.3 Parameter assignment for Comfort Panel
Comfort Panels
Operating Instructions, 07/2017, A5E36770603-AB
157
4.3.12.2
State of the uninterruptible power supply
If you have connected a UPS to a USB port of the HMI device, you can display the
monitoring status of this port.
Requirement
The Control Panel is open.
A UPS is connected to the 24 V DC connection and the USB port of the HMI device.
The "Uninterruptable Power Supply (UPS) with USB support" option was transferred to
the HMI device with ProSave.
UPS settings are configured.
Procedure
1. Open the "UPS Properties" dialog using the "UPS" icon.
2. Change to the "Current status" tab.
3. Refresh the monitoring status with "Update", if needed.
4. Confirm your entries with "OK".
The current monitoring state for the UPS is displayed.
See also
Setting the uninterruptible power supply (Page 155)

Table of Contents

Other manuals for Siemens SIMATIC HMI TP2200 Comfort

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC HMI TP2200 Comfort and is the answer not in the manual?

Siemens SIMATIC HMI TP2200 Comfort Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC HMI TP2200 Comfort
CategoryControl Panel
LanguageEnglish

Related product manuals