Parameter Manual
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
135
Machine data
2.3 Channel-specific machine data
Description: This MD is used to set the compressor operating mode.
The units digits, the tens digits and the hundreds digits have different
meanings.
The following options are available:
Units digits:
0: With the compressor, the tolerances specified with MD33100
$MA_COMPRESS_POS_TOL are met for all axes (geometry and orientation axes).
1: With the compressor, the contour tolerances specified with SD42475
$SC_COMPRESS_CONTUR_TOL are active for the geometry axes.
For the orientation axes, the axis-specific tolerances MD33100
$MA_COMPRESS_POS_TOL are active.
2: With the compressor, the axis-specific tolerances MD33100
$MA_COMPRESS_POS_TOL become active for the geometry axes. The orientation
movement is compressed in compliance with the maximum angular deviations
specified with SD42476 $SC_COMPRESS_ORI_TOL or SD42477
$SC_COMPRESS_ORI_ROT_TOL.
3: With the compressor, the contour tolerance SD42475
$SC_COMPRESS_CONTUR_TOL becomes active for the geometry axes and the maximum
angular deviation SD42476 $SC_COMPRESS_ORI_TOL or SD42477
$SC_COMPRESS_ORI_ROT_TOL becomes active for the orientation axes.
Tens digits:
The tens digits of this MD can be used to set a compressor response that is
compatible with previous software releases (< SW 6.3).
0x: All blocks with orientations and value assignments are compressed.
This is the default setting.
Notice: This response is incompatible with previous software releases!
1x: Blocks with value assignments are not compressed (e.g. X=100 ..., etc.)
2x: Blocks with a programmed tool orientation are not compressed.
(e.g. A3= B3= C3=).
3x: All blocks with value assignments and/or programmed tool orientation are
not compressed. With this setting, the response is fully compatible with pre-
vious software releases (< 6.3).
Hundreds digits:
The hundreds digit can be used to set which blocks in addition to G01 blocks
are to be compressed or not:
0xx: Circular blocks and G00 blocks are not compressed. Is compatible with
previous releases.
1xx: Circular blocks are linearized and compressed by COMPCAD.
2xx: G00 blocks are compressed; a different tolerance may be applied here
(see MD 20560 $MC_G0_TOLERANCE_FACTOR).
3xx: Combination of the two previous options: Both circular blocks and G00
blocks are compressed.
The thousands digits optimize the compressor for different machine types:
0xxx: Optimization for a good surface quality in tool and mold building.
20482 COMPRESSOR_MODE EXP F2
- Mode of compressor DWORD NEW CONF
-
808d-me42 - 0, 0, 0, 0, 0, 0, 0, 0... 0 1333 1/1
808d-me62 - 300 0 1333 1/1
808d-te42 - 0, 0, 0, 0, 0, 0, 0, 0... 0 1333 0/0
808d-te62 - 0, 0, 0, 0, 0, 0, 0, 0... 0 1333 0/0