2
Parameter Manual
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
17
Machine data
2.1 Display machine data
Description: Description
Description: Defines the wait time on read-in of the parameters for all SINAMICS devices
during commissioning
Description: Input limit spindle speed MM+
Description: Input limit cutting meter MM+
Description: Input limit time feed MM+
Description: Input limit rotation feed MM+
Number Identifier Display filters Reference
Unit Name Data type Active
Attributes
System Dimension
Default value
(LIN/ROT)
Minimum
value
(LIN/ROT)
Maximum
value
(LIN/ROT)
Protection
1091 SINAMICS_IBN_TIMEOUT_VALUE --
- Wait time when reading in parameters for Sinamics
commissioning
DWORD Immediately
-
- - 230 0 1000 3/3
1092 MAX_SPINDEL_SPEED_MANUAL_MA --
- Input limit spindle speed MM+ DOUBLE Immediately
-
- - 99999.00000 0 99999.00000 2/2
1093 MAX_SPEED_G96_MANUAL_MA --
- Input limit cutting meter MM+ DOUBLE Immediately
-
- - 99999.00000 0 99999.00000 2/2
1094 MAX_FEEDRATE_G94_MANUAL_MA --
- Input limit time feed MM+ DOUBLE Immediately
-
- - 99999.00000 0 99999.00000 2/2
1095 MAX_FEEDRATE_G95_MANUAL_MA --
- Input limit rotation feed MM+ DOUBLE Immediately
-
- - 99999.00000 0 99999.00000 2/2