Parameter Manual
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
453
PLC User Interface
5.10 PLC machine data
5.10.2 HEX values (MD 14512 USER_DATA_HEX)
5.10.3 FLOAT values (MD 14514 USER_DATA_FLOAT)
5.10.4 User alarm: Configuring (MD 14516 USER_DATA_PLC_ALARM)
DB4500 Signals from NCK [r8]
NCK -> PLC interface
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
1000 Hex value (BYTE)
1001 Hex value (BYTE)
1002 Hex value (BYTE)
1003 Hex value (BYTE)
... ...
1030 Hex value (BYTE)
1031 Hex value (BYTE)
DB4500 Signals from NCK [r32]
NCK -> PLC interface
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
2000 Float value (REAL/4 byte)
2004 Float value (REAL/4 byte)
2008 Float value (REAL/4 byte)
2012 Float value (REAL/4 byte)
2016 Float value (REAL/4 byte)
2020 Float value (REAL/4 byte)
2024 Float value (REAL/4 byte)
2028 Float value (REAL/4 byte)
DB4500 Signals from NCK [r8]
NCK -> PLC interface
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
3000 Alarm response/cancel criteria, alarm 700000
3001 Alarm response/cancel criteria, alarm 700001
3002 Alarm response/cancel criteria, alarm 700002
... ...
3247 Alarm response/cancel criteria, alarm 700247
Note
You can refer to SINUMERIK 808D ADVANCED Commissioning Manual
for the information
about how to configure the user alarms.