NC setting data
Description: Description
Description: This setting data defines the number of increments when variable increment
(INCvar) is selected. This increment size is traversed by the axis in JOG
mode each time the traverse key is pressed or the handwheel is turned one
detent position and variable increment is selected (PLC interface signal
"Active machine function: INC variable" for machine or geometry axes is set
to 1). The defined increment size also applies to DRF.
Note:
Please note that the increment size is active for incremental jogging and
handwheel jogging. So, if a large increment value is entered and the hand-
wheel is turned, the axis might cover a large distance (depends on setting in
MD31090 $MA_JOG_INCR_WEIGHT).
SD irrelevant to ......
JOG continuous
Related to ....
NC/PLC interface signal DB3300 DBX1001.5,1005.5,1009.5 (Geometry axis 1-3
active machine function: INC variable) or NC/PLC interface signal DB390x
DBX5.5 (Active machine function: INC variable)
MD31090 $MA_JOG_INCR_WEIGHT (weighting of an increment for INC/handwheel)
Number Identifier Display filters Reference
Unit Name Data type Active
Attributes
System Dimension
Default value
(LIN/ROT)
Minimum
value
(LIN/ROT)
Maximum
value
(LIN/ROT)
Protection
41010 JOG_VAR_INCR_SIZE -H1
- Size of the variable increment for JOG DOUBLE Immediately
-
- - 0. - - 7/7