NC setting data
Parameter Manual
310
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
Description:
This SD can be used to set the method of operation of the dry run velocity
set by SD42100 $SC_DRY_RUN_FEED.
The following values are possible:
0:
The maximum of SD42100 $SC_DRY_RUN_FEED and the programmed velocity become
active. This is the standard setting and corresponds to the behavior up to SW
5.
1:
The minimum of SD42100 $SC_DRY_RUN_FEED and the programmed velocity become
active.
2:
SD42100 $SC_DRY_RUN_FEED becomes active directly, irrespective of the pro-
grammed velocity.
The values 3...9 are reserved for extensions.
10:
As configuration 0, except for thread cutting (G33, G34, G35) and tapping
(G331, G332, G63). These functions are executed as programmed.
11:
As configuration 1, except for thread cutting (G33, G34, G35) and tapping
(G331, G332, G63). These functions are executed as programmed.
12:
As configuration 2, except for thread cutting (G33, G34, G35) and tapping
(G331, G332, G63). These functions are executed as programmed.
Description: Default value for path feedrate, This setting data is evaluated when the part
program starts taking into account the feedrate type active at this time (see
MD20150 $MC_GCODE_RESET_VALUES and MD20154 $MC_EXTERN_GCODE_RESET_VALUES).
Description: Default value for path feedrate in approach blocks (after repos., block
search, SERUPRO etc).
The contents of this settting data are only used when it is non-zero.
It is evaluated like an F word programmed for G94.
42101 DRY_RUN_FEED_MODE -V1
- Mode for dry run velocity BYTE Immediately
-
- - 0, 0, 0, 0, 0, 0, 0, 0... 0 12 7/7
42110 DEFAULT_FEED - V1,FBFA
mm/min Path feed default value DOUBLE Immediately
-
- - 0., 0., 0., 0., 0., 0., 0.,
0....
0.0 - 7/7
42120 APPROACH_FEED --
mm/min Path feedrate in approach blocks DOUBLE Immediately
-
- - 0., 0., 0., 0., 0., 0., 0.,
0....
0.0 - 2/2