Parameter Manual
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
61
Machine data
2.2 General machine data
Description: Set write protection for cycle directory /_N_CST_DIR:
Assigned to the programs:
Value -1: Keep the value currently set
Value 0: Siemens password
Value 1: Machine OEM password
Value 2: Password of setup engineer, service
Value 3: End user password
Value 4: Keyswitch position 3
Value 5: Keyswitch position 2
Value 6: Keyswitch position 1
Value 7: Keyswitch position 0
The machine data can only be written with values 0 and 1, and with the corre-
sponding password also active.
Description: Set write protection for cycle directory /_N_CMA_DIR:
Assigned to the programs:
Value -1: Keep the value currently set
Value 0: Siemens password
Value 1: Machine OEM password
Value 2: Password of setup engineer, service
Value 3: End user password
Value 4: Keyswitch position 3
Value 5: Keyswitch position 2
Value 6: Keyswitch position 1
Value 7: Keyswitch position 0
The machine data can only be written with values 0 and 1, and with the corre-
sponding password also active.
11165 ACCESS_WRITE_CST N01 -
- Write protection for directory /_N_CST_DIR DWORD PowerOn
-
-- -1 -1 7 2/2
11166 ACCESS_WRITE_CMA N01 -
- Write protection for directory /_N_CMA_DIR DWORD PowerOn
-
-- -1 -1 7 2/2
Siemens Controls