Parameter Manual
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
63
Machine data
2.2 General machine data
Description: Set write protection for definition file /_N_DEF_DIR/_N_UACCESS_DEF:
Value 0: Siemens password
Value 1: Machine OEM password
Value 2: Password of setup engineer, service
Value 3: End user password
Value 4: Keyswitch position 3
Value 5: Keyswitch position 2
Value 6: Keyswitch position 1
Value 7: Keyswitch position 0
The machine data can only be written with values 0, 1 and 2, and with the
corresponding password also active.
Description: Either all data or only those data which differ from the default setting can
be set to be output when creating standard archives (ARC) and copying 'NC
active data'.
Bit0(LSB) Effectiveness of the differential upload with INI/TEA files
0: All data are output
1: Only those MDs that have changed in comparison to the compiled values are
output
Bit1 is reserved and acts like bit 0
Bit2 Change to an array element
0: Complete arrays are output
1: Only those elements of an array that have changed are output
Bit3 R parameters (only for INI files)
0: All R parameters are output
1: Only R parameters not equal to '0' are output
Bit4 Frames (only for INI files)
0: All frames are output
1: Only those frames that are not zero frames are output.
Bit5 Tool data (cutting edge parameters) (only for INI files)
0: All tool data are output
1: Only those tool data not equal to '0' are output.
Bit6 Buffered system variables ($AC_MARKER[], $AC_PARAM[] only for INI files)
0: All system variables are output
1: Only those system variables not equal to '0' are output
Bit7 Synchronized actions GUD (for INI files only)
0: All Syna GUD are output
1: Only those Syna GUD not equal to '0' are output
Active: The change in the data becomes active on the start of the upload for
the next range.
The settings are only active, if MD11212 $MN_UPLOAD_CHANGES_ONLY=FALSE.
11172 ACCESS_WRITE_UACCESS N01 -
- Write protection for _N_UACCESS_DEF BYTE PowerOn
-
-- 7 0 7 3/3
11210 UPLOAD_MD_CHANGES_ONLY N01, N05 IAD
- Machine data backup of changed machine data only BYTE Immediately
-
- - 0x0F 0 - 2/2
Siemens Controls

Table of Contents

Other manuals for Siemens SINUMERIK 808D ADVANCED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 808D ADVANCED and is the answer not in the manual?

Siemens SINUMERIK 808D ADVANCED Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 808D ADVANCED
CategoryControl Unit
LanguageEnglish

Related product manuals