Machine data
2.2 General machine data
Parameter Manual
88
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
Description:
Maximum number of log files in the passive file system.
The individual values involve the users of the logging function, which are
assigned the following functions:
0: Reserved for system functions: simultaneous recording, simulation, syn-
chronized actions analysis
1: Reserved for system functions: determining program runtimes, multi-step
editor
2: Reserved for OEM applications
3: Reserved for OEM applications
4: Reserved for OEM applications
5: Reserved for system functions: trace
6: Reserved for system functions: trace
7: Reserved for system functions: trace
8: Reserved for system functions: trace
9: Reserved for system functions: action log
Description: Number of standard data lists in the OPI module ETPD (user-specific).
The individual values involve the users of the logging function, which are
assigned the following functions:
0: Reserved for system functions: simultaneous recording, simulation, syn-
chronized action analysis
1: Reserved for system functions: determining program runtimes, multi-step
editor
2: Reserved for OEM applications
3: Reserved for OEM applications
4: Reserved for OEM applications
5: Reserved for system functions: trace
6: Reserved for system functions: trace
7: Reserved for system functions: trace
8: Reserved for system functions: trace
9: Reserved for system functions: action log
18370 MM_PROTOC_NUM_FILES N02 D1,OEM
- Max.no. of log files in passive file system DWORD PowerOn
-
- 10 2, 2, 0, 0, 0, 2, 2, 2... 2, 2, 0, 0, 0, 2, 2,
2...
10, 10, 10, 10,
10, 10, 10, 10...
1/1
18371 MM_PROTOC_NUM_ETPD_STD_LIST N02 D1,OEM
- Number of standard data lists ETPD. DWORD PowerOn
-
- 10 25, 6, 0, 0, 0, 25, 25,
25...
25, 6, 0, 0, 0,
25, 25, 25...