05.2006 Parameterization
SIEMENS AG 6SE7087-2JD60
SIMOVERT MASTERDRIVES Operating Instructions 8-9
8.3.2.2 Starting the USS bus scan
DriveMonitor starts with an empty drive window. Via the menu "Set up
an ONLINE connection..." the USS bus can be scanned for connected
devices:
Fig. 8-5 Starting the USS bus scan
The "Set up an online connection” menu is only valid from Version 5.2
onwards.
Fig. 8-6 Search for online drives
During the search the USS bus is scanned with the set baudrate only.
The baud rate can be changed via "Tools
Æ
ONLINE Settings", see
section 8.3.2.1.