05.2006 Technical Data
Siemens AG 6SE7087-2JD60
SIMOVERT MASTERDRIVES Operating Instructions 13-11
Order No. Power loss Cooling- Maximum
Typical pressure drop
(at 2.5 kHz)
[kW]
water
require-
ment
*)
[l/min]
additional heat-
dissipation power
at Tair 30 °C
[kW]
according to volumetric flow
Rated input voltage 3 AC 380 to 480 V
6SE7021-3EB61-1AA1 0.21 1.00 0.1 0.15 to 0.2 bar at 1.2 l/min
6SE7021-8EB61-1AA1 0.16 1.20 0.1 0.15 to 0.2 bar at 1.2 l/min
6SE7022-6EC61-1AA1 0.33 2.10 0.2 0.15 to 0.2 bar at 2.6 l/min
6SE7023-4EC61-1AA1 0.47 2.60 0.2 0.15 to 0.2 bar at 2.6 l/min
6SE7023-8ED61-1AA1 0.58 4.25 0.5 0.15 to 0.2 bar at 6.0 l/min
6SE7024-7ED61-1AA1 0.71 4.80 0.5 0.15 to 0.2 bar at 6.0 l/min
6SE7026-0ED61-1AA1 0.86 5.25 0.5 0.15 to 0.2 bar at 6.0 l/min
6SE7027-2ED61-1AA1 1.07 6.00 0.5 0.15 to 0.2 bar at 6.0 l/min
Rated input voltage 3 AC 500 to 600 V
6SE7014-5FB61-1AA1 0.09 0.80 0.1 0.15 to 0.2 bar at 1.2 l/min
6SE7016-2FB61-1AA1 0.11 0.85 0.1 0.15 to 0.2 bar at 1.2 l/min
6SE7017-8FB61-1AA1 0.12 0.90 0.1 0.15 to 0.2 bar at 1.2 l/min
6SE7021-1FB61-1AA1 0.16 1.00 0.1 0.15 to 0.2 bar at 1.2 l/min
6SE7021-5FB61-1AA1 0.21 1.20 0.1 0.15 to 0.2 bar at 1.2 l/min
6SE7022-2FC61-1AA1 0.32 2.00 0.2 0.15 to 0.2 bar at 2.6 l/min
6SE7023-0FD61-1AA1 0.59 3.10 0.5 0.15 to 0.2 bar at 6.0 l/min
6SE7023-4FD61-1AA1 0.69 3.45 0.5 0.15 to 0.2 bar at 6.0 l/min
6SE7024-7FD61-1AA1 0.87 4.15 0.5 0.15 to 0.2 bar at 6.0 l/min
Table 13-9 Water-cooled converter
These units and the air-cooled converters are identically constructed.
Instead of the heat sink for air, an air/water cooler has been installed.
All the technical data not listed in Table 13-9 for a particular unit are the
same as those of the air-cooled converter. The first 12 positions of the
Order No. are identical. The supplement "-1AA1” indicates water
cooling.
Water-cooled
converter
NOTE
*)
The cooling water requirement applies for the unit rating of the converter and 100%
utilization of the additional heat dissipation obtained from a water temperature rise
intake/return of T = 5 K.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Vector Control and is the answer not in the manual?

Siemens Vector Control Specifications

General IconGeneral
BrandSiemens
ModelVector Control
CategoryMedia Converter
LanguageEnglish

Related product manuals