User Manual of A90 Series Inverter
241
Deceleration time for quick stop
0.00 - 650.00
(F15.13=0)
0.0 - 6500.0
(F15.13=1)
0 - 65000
(F15.13=2)
Set the acceleration and deceleration time during rapid stop.
7.17 Virtual I/O Function Parameter Group of F17 Group
The standard A90 series inverter is equipped with eight virtual multi-function input
terminals (VX1 to VX8), of which the functions and usages are basically the same as those
of the actual input terminals. Differences are described below. For their similarities, refer to
the parameter description of the digital input terminal function options of the F02 group.
VX1 virtual input
function options
The same as the digital input
terminal function options of the
F02 group. See the function list of
the digital multi-function input
terminal in Table 7-2.
VX2 virtual input
function options
VX3 virtual input
function options
VX4 virtual input
function options
VX5 virtual input
function options
VX6 virtual input
function options
VX7 virtual input
function options
VX8 virtual input
function options
Virtual input
positive/negative logic
0: positive logic, valid in the
closed state/invalid in the open
state
1: Negative logic, invalid in the