User Manual of A90 Series Inverter
14
1.2 Detailed Introduction to Running Status of A90 series Inverter
1.2.1
Working status of inverter
The working status of A90 series inverter is divided into: parameter setting status,
normal running status, jog running status, self-learning running status, stop status, jog stop
status and fault status.
Parameter setting status: After being powered on and initialized, the inverter will
be in the standby status with no fault or start command, and have no output.
Normal running status: Upon receiving a valid start command (from the keyboard,
control terminal and communication), the inverter will have the output based on
the set input requirements, driving the motor to rotate.
Jog running status: This is enabled by the keyboard, external terminal or
communication, driving the motor to rotate at the jog input speed.
Self-learning running status: This is enabled by the keyboard, detecting relevant
parameters of the motor in the stationary or rotating status.
Stop status: It is a process for the output frequency to decrease to zero according
to the set deceleration time in the case of invalid operating commands.
Jog stop status: It is a process for the output frequency to decrease to zero
according to the jog deceleration time in the case of invalid jog operating
commands.
Fault status: Refer to the inverter status in the case of each fault.
1.2.2
Running mode of inverter
The running mode of the inverter refers to the control law of the inverter to drive the
motor to rotate at the required speed and torque. The running mode includes:
General open-loop space vector control-VVF control: suitable for applications
where the speed is not changing fast and there are not high requirements for the
accuracy of rotating speed, and most AC motor drives.
Speed sensorless vector control-SVC control: advanced speed estimation
algorithm, involving open-loop vector control and high control accuracy but no
encoder.
1.2.3
Set mode of inverter
The set mode of the inverter refers to the physical quantity that is taken as the
controlled target when the inverter drives a motor.
Speed setting mode with the motor speed as controlled target