User Manual of A90 Series Inverter
297
Send the invoice to
Normal Return
Exception Return
*
Frame header
≥3.5 characters (idle)
1
Address
01
Address
01
Address
01
2
Function code
41
Function code
41
Function code
C1
3
Register address
Hi
70
Register address Hi
70
Exception code
04 (assumption)
4
Register address
L
o
00
Register address Lo
00
CRC check Lo
70
5
Register value Hi
00
Register value Hi
00
CRC check Hi
53
6
Register value
L
o
01
Register value Lo
01
7
CRC check Lo
E
6
CRC check Lo
E6
8
CRC check Hi
C
5
CRC check Hi
C5
*
Tail
≥3.5 characters (idle)
2)
Free stop of inverter
Send: 01 41 70 0000 07 66 C7
Return:
01 41 70 0000 07 66 C7 (normal)
Return:
01 C1 04 70 53 (exception, assuming a slave fault)
Send the invoice to
Normal Return
Exception Return
*
Frame header
≥3.5 characters (idle)
1
Address
01
Address
01
Address
01
2
Function code
41
Function code
41
Function code
C1
3
Register address
Hi
70
Register address Hi
70
Exception code
04 (assumption)
4
Register address
L
o
00
Register address Lo
00
CRC check Lo
70
5
Register value Hi
00
Register value Hi
00
CRC check Hi
53
6
Register value
L
o
07
Register value Lo
07
7
CRC check Lo
66
CRC check Lo
66
8
CRC check Hi
C
7
CRC check Hi
C7
*
Tail
≥3.5 characters (idle)