- 92 -
No.EX##-OMY0004
Code
Additional Information
Brief Description
Solution
0x02EX
736dez
737dez
738dez
739dez
The least significant four bits
display information on the
affected shutdown path of the
watchdog module or outputs.
Range of values:
0: M
1: Zone Z1
2: Zone Z2
3: Zone Z3
Hardware test error
detected regarding the
shutdown path via the
watchdog module.
An error was detected during the test by briefly
switching off via the watchdog module. The test
error could indicate a hardware error regarding the
switching off capacity of the watchdog module or a
cross-circuit between outputs or between the
output and external signal. As a result, until error
acknowledgement all outputs are also returned to a
safe state via the common shutdown paths. The
error is displayed on the device by the red
illuminated output LEDs.
An acknowledgement of this diagnostic message,
provided there are no other relevant error
messages present, deletes the message, cancels
the red LEDs and restarts the outputs.
0x012X
288dez
289dez
290dez
291dez
296dez
297dez
298dez
299dez
The least significant four bits
display information on the
affected input.
Range of values:
0: IN0
1: IN1
2: IN2
3: IN3
8: IN4
9: IN5
A: IN6
B: IN7
Cross-circuit on the
displayed input.
A cross-circuit was detected to another input or to
an external clock output. The affected input is
maintained in a safe state. An acknowledgement of
this diagnostic message is possible. The
acknowledgement deletes the message and
releases the affected input provided no other errors
are present.
0x013X
304dez
305dez
306dez
307dez
The least significant four bits
display information on the
affected input pair.
Range of values:
0: IN0, IN4
1: IN1, IN5
2: IN2, IN6
3: IN3, IN7
Symmetry violation at
the displayed input.
At an input pair in the two-channel mode a violation
of the parameterised symmetry was detected. This
is only used for the evaluation of contacts in the
connected switches.
In the event that the switch-on lock is activated
during the symmetry violation the inputs are
blocked until the acknowledgement of the
diagnostic message. Otherwise the input
information continues to be captured and sent to
the safe control system. An acknowledgement of
this diagnostic message is possible. The
acknowledgement deletes the message.
0x014X
320dez
321dez
322dez
323dez
328dez
329dez
330dez
331dez
The least significant four bits
display information on the
affected input.
Range of values:
0: IN0
1: IN1
2: IN2
3: IN3
8: IN4
9: IN5
A: IN6
B: IN7
Hardware error at the
displayed input.
A hardware error was detected at the displayed
input by performing internal tests. An
acknowledgement of this diagnostic message is
possible. The acknowledgement only deletes the
message. The restart is only possible after an
error-free power-up self-test.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks EX245-FPS1 and is the answer not in the manual?

SMC Networks EX245-FPS1 Specifications

General IconGeneral
BrandSMC Networks
ModelEX245-FPS1
CategoryControl Unit
LanguageEnglish

Related product manuals