-54-
No.PF※※-OMJ0006-G
Specification
■Specifications
Dry air, N
2
, Ar, CO
2
(air quality class to ISO8573-1 1.1.2 to 1.6.2)
Min. setting/display unit
Setting/display flow range
3
Min. setting/display unit
Accumulated flow volume per
pulse
Instantaneous flow: L/min, CFM x 10
-2
Accumulated flow: L, ft
3
x 10
-1
Standard condition (ANR), Normal condition (NOR)
±1%F.S. max. (fluid: Dry air)
Analogue output accuracy: ±3%F.S. max.
±5%F.S. max. (0.35 MPa reference)
Temperature characteristics
±2%F.S. max. (15 to 35 C)
±5%F.S. max. (0 to 15 C, 35 to 50 C)
NPN or PNP open collector output
NPN output: 1 V (at 80 mA), PNP output: 1.5 V or less (at 80 mA)
1 s (50 ms, 0.5 s, 2 s are selectable)
Hysteresis mode, window comparator mode,
Accumulated output mode, Accumulated pulse output mode
Output voltage: 1 to 5 V
Output impedance: 1 kΩ
Output current: 4 to 20 mA
Max. load impedance: 600 Ω (24 VDC)
Min. load impedance: 50 Ω